Measurement of Indoor Radon Gas Concentration in same Region of Baghdad Governorate Using CR-39 Nuclear Track Detector

Main Article Content

Ruwiadah Tarek Mahdi

Abstract

In this research the activity of radon gas in air in Baghad governorate,Iraq, using “alpha-emitters track registration (CR-39) track detector were measured. This measurement was done for selected areas from Baghdad Governorate, The results obtained shows that the highest average concentrations for Rn-222 is (179.077 Bq/m^3) which was recorded within Al-Shaaib city and less average concentrations was (15.79 Bq/m^3) in the nearby residential area of Baghdad International Airport and the overall average concentrations is (86.508 Bq/m^3) for these regions.
Then the radon concentration was measured annual effective dose calculated from radon concentration and found in range from 0.4031 mSv/y to 4.5179 mSv /y with an average value of 2.1824 mSv/y. The annual effective dose of radon was within the allowed international limits.

Article Details

How to Cite
1.
Measurement of Indoor Radon Gas Concentration in same Region of Baghdad Governorate Using CR-39 Nuclear Track Detector. Baghdad Sci.J [Internet]. 2017 Dec. 3 [cited 2024 Mar. 19];14(4):0688. Available from: https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/2411
Section
article

How to Cite

1.
Measurement of Indoor Radon Gas Concentration in same Region of Baghdad Governorate Using CR-39 Nuclear Track Detector. Baghdad Sci.J [Internet]. 2017 Dec. 3 [cited 2024 Mar. 19];14(4):0688. Available from: https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/2411

Similar Articles

You may also start an advanced similarity search for this article.