Design and develop an optical setup related to the pump-probe technique for spectroscopic study

Authors

  • Saad Kh. Rahi Rahi Department of Physics, College of Science, Mustansiriyah University, Iraq, Baghdad https://orcid.org/0000-0001-8631-2918
  • Muayyed J. Zoory Zoory Department of Physics, College of Science, Mustansiriyah University, Iraq, Baghdad
  • Alaa H. Ali Ministry of Science and Technology, Iraq, Baghdad https://orcid.org/0000-0002-3076-981X

DOI:

https://doi.org/10.21123/bsj.2023.8383

Keywords:

Delay time, Integration time, Optical detector, Pulse Width, Pump-Probe technology

Abstract

In this research, an optical system using Pump-Probe technology was designed to study the effect of changing the Frequency values, integration time, delay time, and laser pulse width on the pumping pulse energy on an arbitrary laser dye material with an absorption coefficient of about 650 nm. we found that decreasing the pumping time to 10% of the pulse time is not suitable for the pump-probe technique because there is no resonance between the pumping time and the detector response to the source used. Also, we indicate that increasing the pumping time to 20% of the pulse time results in the highest possible detector response at an integration time 150 μs in the pump-probe technique. therefore, we noted that the detector response becomes more suitable for working in the pump-probe technique as the pumping time increases, as well as the efficiency of the detector, which increases significantly as the pumping time increases, as well as the integration time for the same delay time, it is more stable at 20% pumping time and collection time 150 μs at a delay time of 12.4 ns.

 

 

References

Hashimoto KY, Kashiwa K, Wu N, Omori T, Yamaguchi M, Takano O, et al. A laser probe based on a Sagnac interferometer with fast mechanical scan for RF surface and bulk acoustic wave devices. IEEE Trans Ultrason Ferroelectr Freq Control. 2011; 58(1): 187-194. https://dx.doi.org/10.1109/TUFFC.2011.1785 .

Biesheuvel J, Karr JP, Hilico L, EikemKSE, Ubachs W, Koelemeij JCJ. Probing QED and fundamental constants through laser spectroscopy of vibrational transitions in HD+. Nat Commun. 2016; 7: 10385. https://doi.org/10.1038/ncomms10385 .

Komotskii VA, Sokolov YM, Basistyi EV. Depth Measurement of the Periodic Grooved Reflectors of Surface Acoustic Waves Using the Laser Probing. J Commun Technol Electron. 2011; 56(2): 220–225. https://doi.org/10.1134/S1064226910121125 .

Harilal SS, Brumfield BE, LaHaye NL, Hartig KC, Phillips MC. Optical spectroscopy of laser-produced plasmas for standoff isotopic Analysis. Appl Phys Rev. 2018; 5: 021301. https://dx.doi.org/10.1063/1.5016053.

Giulio C, Cristian M, Larry L, Dario P. Time-resolved methods in biophysics. 4. Broadband pump–probe spectroscopy system with sub-20 fs temporal resolution for the study of energy transfer processes in photosynthesis. Photochem Photobiol Sci. 2007; 6(2): 135–144. https://doi.org/10.1039/B606949E

Wu N, Hashimoto Ky, Kashiwa K, Omori T, Yamaguchi M. Study on the frequency dependence of lateral energy leakage in RF BAW device by fast-scanning laser probe system. IEEE Int Ultrason Symp. 2008 Nov. 2‐5; Beijing, China. https://dx.doi.org/10.1109/ULTSYM.2008.0023 .

Yahya KA. Enhancement of Electron Temperature under Dense Homogenous Plasma by Pulsed Laser Beam. Baghdad Sci J. 2021 Dec; 18(4): 1344. https://doi.org/10.21123/bsj.2021.18.4.1344 .

Emre K, Gokhan G. A comparison of fuzzy logic and PID controller for a single-axis solar tracking system. Renewables Wind Water and Solar. 2016 3(1): 7. https://dx.doi.org/10.1186/s40807-016-0023-7

Naif HA, Saeed AA, Al-Kadhemy MFH. Spectral Behaviour of the low concentrations of Coumarin 334 with Broadband Cavity Enhanced Absorption Spectroscopy. Baghdad Sci J. 2022 Apr; 19(2): 0438. https://dx.doi.org/10.21123/bsj.2022.19.2.0438

Raied KJ, Russul KR. Studying the Effect of Laser Pump Pulse Energy and Delay Time on conversion Efficiency of KTP. Iraqi J Sci. 2020; 61(2): 351-357. https://dx.doi.org/10.24996/ijs.2020.61.2.13.

Dong PT, Cheng JX. Pump-Probe Microscopy Theory Instrumentation and Applications. Spectroscopy. 2017; 32(4): 24-36. https://sites.bu.edu/cheng-group/files/2017/10/8-Pu-Ting-Dong-Pump-probe-review-in-Spectroscopy.pdf

. Anchi Y, Xiong Y, Dan I, Wenxiang C, Paul MC, Two-color pump-probe laser spectroscopy instrument with picosecond time-resolved electronic delay and extended scan range. Rev Sci Instrum. 2005; 76: 114301. https://dx.doi.org/10.1063/1.2126808.

Abramczyk H. Introduction to Laser Spectroscopy. Elsevier. 1st Edition, 2005.

Liangkun H, Quan W, Jian H, Fan Y, Hongjie L, Zhiyu W. Miniature Broadband NIR Spectrometer Based on FR4 Electromagnetic Scanning Micro-Grating. Micromachines. 2020; 11: 393. https://dx.doi.org/10.3390/mi11040393.

Downloads

Issue

Section

article

How to Cite

1.
Design and develop an optical setup related to the pump-probe technique for spectroscopic study. Baghdad Sci.J [Internet]. [cited 2024 Apr. 30];21(6). Available from: https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/8383