Improvement the bearing capacity of the soil which is supporting the shallow foundation by using bored short micro-piles
محتوى المقالة الرئيسي
الملخص
In this paper , concrete micro-piles were used to improve the bearing capacity of the soil which is supporting the shallow foundation by using groups of (4; 6 and 9)bored short micro-piles which have, (D=0.125m and D=0.1m), and length to diameter ratio (L/D) equal to (6; 10 and 12) respectively.
To calculate the bearing capacity of the micro-piles,(Tomlinson) and (Lamda) methods were used; also the soil properties were taken from Al-Muthana airport,(Al-Qyssi,2001) [1].
The results show that; increasing the number of piles and/ or the diameters and lengths; and the interaction between the bearing capacity of the shallow foundation with the bearing capacity of the pile group which leads to increasing the strength against the external loads; and the maximum bearing capacity was, when 9 piles with (L/D=12) was used. The improving ratio in the bearing capacity was (90%) compared with the bearing capacity of a (1×1) m shallow foundation without any piles.
The results show that, the Tomlinson method of analysis produce lower results than the Lamda method by a ratio of (2-6) %. The results show also that the use of bored short micro-piles with (D=0.125m); (L/D=12) and number of 4-piles better than the (9) bored short micro-piles which have (D=0.1m).
To calculate the bearing capacity of the micro-piles,(Tomlinson) and (Lamda) methods were used; also the soil properties were taken from Al-Muthana airport,(Al-Qyssi,2001) [1].
The results show that; increasing the number of piles and/ or the diameters and lengths; and the interaction between the bearing capacity of the shallow foundation with the bearing capacity of the pile group which leads to increasing the strength against the external loads; and the maximum bearing capacity was, when 9 piles with (L/D=12) was used. The improving ratio in the bearing capacity was (90%) compared with the bearing capacity of a (1×1) m shallow foundation without any piles.
The results show that, the Tomlinson method of analysis produce lower results than the Lamda method by a ratio of (2-6) %. The results show also that the use of bored short micro-piles with (D=0.125m); (L/D=12) and number of 4-piles better than the (9) bored short micro-piles which have (D=0.1m).
تفاصيل المقالة
كيفية الاقتباس
1.
Improvement the bearing capacity of the soil which is supporting the shallow foundation by using bored short micro-piles. Baghdad Sci.J [انترنت]. 7 أكتوبر، 2024 [وثق 19 ديسمبر، 2024];7(1):788-800. موجود في: https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/2923
القسم
article
هذا العمل مرخص بموجب Creative Commons Attribution 4.0 International License.
كيفية الاقتباس
1.
Improvement the bearing capacity of the soil which is supporting the shallow foundation by using bored short micro-piles. Baghdad Sci.J [انترنت]. 7 أكتوبر، 2024 [وثق 19 ديسمبر، 2024];7(1):788-800. موجود في: https://bsj.uobaghdad.edu.iq/index.php/BSJ/article/view/2923